Tuesday, 12 May 2015

My new consumer unit london kent essex

What to do with a new consumer unit


New Consumer units was introduced under the last IEE wiring regulations BS7671, when this happened under the 17th edition it was stated that all consumer units must have protection via an RCD for all cables embedded in walls except circuits of a high integrity nature, these circuits where deemed to include burglar alarms, smoke alarms, heat alarms etc.


New consumer units are made up of several electrical components but the main ones that would be visible to you would be as follows we have also included a short guide for if they trip;


MCBs (Miniature Circuit Breakers) For a consumer unit


An MCB will switch off in the event of an overload or a short circuit here is a step by step guide to reset it;
1. Switch off and unplug all appliances and check to see if the is any damage
2. Reset the MCB that has tripped to do this it should usually be pushed into the up position, this should reset the electricity supply to that circuit
3. If the MCB does not switch on call Trade Certificates on 02036371446


 


RCD (Residual Current Device) For a consumer unit


 


An RCD protects against an electrical current flowing to earth and some faults can be momentary, you can find some extra information on it on our page about what happens if my RCD trips or you can use our quick guide below
1. Switch off all MCBs.
2. Switch on RCD.
3. Switch on each MCB in turn. This should reset the system.
4. If the RCD switches off again when an MCB is switched on, there is a fault.
5. If the RCD cannot be switched on with the MCBs in the “OFF” position, call Trade Certificates on 02036371446


 


Consumer Unit with Trade Certificates in London, Kent Essex

Switches on a consumer unit


 


The new consumer unit would have a dual RCD and in most cases be set up in the following ways


RCD 1


  • Upstairs Lights,
    get-a-hi-integrity-Consumer-unit-replacement-in-London-kent-and-essex-with-Trade-certificates

    High Integrity consumer Unit


  • Downstairs Ring Final,

  • Garage Sockets,

  • Shower

RCD 2


  • Downstairs Lights,

  • Upstairs Sockets,

  • Cooker,

  • Heating,

 


The reason for the new consumer units being set up in this way is by alternating them only one part of the supply will get interrupted in case of a short circuit, overload or any other fault occurs.


If there is not the space to install a dual RCD consumer unit in your property then the alternative method would be to use RCBO’s which is a combined RCD and MCB, we do promote this as it can be quite expensive to our customers but if required this would be the only option that we would follow.


If you require a new consumer unit or advice please call Trade Certificates on 02036371446


My new consumer unit london kent essex

Trade Electricians - Part of the TFS PLC group

Trade Electricians is a new website brought to you by TFS PLC, our other main sites are tradecertificates.co.uk and tradeheatingengineer.co.uk

Find out more about Trade Electricians and visit us today

Test Post from Trade Electricians

Test Post from Trade Electricians http://tradeelectricians.co.uk

Test Post from Landlord Electrical Certificates and Gas Certificates

Test Post from Landlord Electrical Certificates and Gas Certificates http://tradecertificates.co.uk

Tuesday, 5 May 2015

Changes to an electrical installation condition report ( Electrical Certificate)

Electrical Installation Condition Report (electrical certificate)


 


There are changes to your electrical installation condition report or otherwise known as a electrical certificate, below we have highlighted the changes by each section so make sure you don’t get caught out.


 


Section D (Extent and limitations of inspection and testing)


More text has been added here to the electrical certificate so that information can be added in regards to the roof space and the accessibility to the electrical equipment with that space.


Section J (Particulars of installation referred to in the report)


This part of the electrical installation condition report now includes tick boxes for the main bonding conductor connections to not only gas and water pipes but also structural steel, oil pipes, lightning protection and any other parts to ensure all electrical connections have been checked for polarity.


Electrical installation condition report


Section K (Observations)


“FI” is now recognised as a code which means “further investigation”, for this part of the electrical installation condition reports the yes and no column for this has been deleted but the code it self can be added for clarity to ensure it is not missed when carrying out remedial works.


Note 9 for the notes of the person producing the electrical installation condition report


The place in which the electrical testing has revealed a deficiency that could not be fully identified due the the limitations set out for the electrical inspection, The note shows where a further investigation is required and a code should be given of either Code 1 (Danger Present or Code 2 (Potential Danger). If the is the case the FI classification should be recorded in section K as explained above.


Notes 7 and 8 are for recipients receiving the electrical installation condition report


Here the notes refer to a skilled person competent in electrical installation work instead of a competent person, this has been done so that it is pointed out that it should be a qualified electrician carrying out the remedial works rather than a unqualified tradesman.


Note 10 are for the recipients post remedial testing of the electrical certificate


Here the notes refer to a skilled person competent in electrical installation work instead of a competent person, this has been done so that it is pointed out that it should be a qualified electrician carrying out the remedial works rather than a unqualified tradesman.


Additions have also been made to the electrical installation condition report under the schedule guidance for the inspector and also for domestic and similar premises with upro a 100A supply, these changes are more comprehensive checklists than they were previously.


 


If you need a qualified electrician…….. Call Trade Certificates for your electrical installation condition report and remedials


Trade Certificates have fully qualified and regulated electricians in London, Kent and Essex for all electrical testing, certificates, installations and maintenance. If you need an electrician the same day or for planned works call us today on 02036371446



Changes to an electrical installation condition report ( Electrical Certificate)

Monday, 27 April 2015

Get all your gas and electrical certificate information and bookings with Trade Certificates

Trade Certificates write about quick fixes for your gas and electrical problems so you don't always have to call an engineer, but if the worst happens we are always here to help.

Visit our site and find out more of what we can do and how we can help.

Sunday, 26 April 2015

Electrical Safety Certificate & Gas Safety Certificate | Book your today with Trade Certificates

Book your Electrical and gas Safety certificates with Trade Certificates today, for more information on all our services our site or call Trade Certificates